吴优,许金水,宋庆,李长生,蓝志英,张黎.周围性面瘫面肌萎缩定量超声图像与临床表现的相关性初探[J].实用中西医结合临床,2021,21(18):
周围性面瘫面肌萎缩定量超声图像与临床表现的相关性初探
Preliminary Study on the Correlation of Surrounding Mega Parallemia Atrophy Quantitative Ultrasound Image and Clinical Manifestation
投稿时间:2021-06-30  修订日期:2021-07-22
DOI:
中文关键词: 周围性面瘫  面肌萎缩  面部超声  厚度对比  临床相关性
英文关键词: Peripheral facial paralysis  Facial muscle atrophy  Facial ultrasound  Thickness contrast  Clinical relevance
基金项目:
作者单位E-mail
吴优 江西中医药大学2019级针灸推拿专硕 809060978@qq.com 
许金水* 江西中医药大学附属医院 419236934@qq.com 
宋庆 江西中医药大学附属医院超声科  
李长生 江西中医药大学2019级针灸推拿专硕  
蓝志英 江西中医药大学2020级针灸推拿专硕  
张黎 江西中医药大学2020级针灸推拿专硕  
摘要点击次数: 479
全文下载次数: 183
中文摘要:
      目的:本研究通过超声成像技术,探讨面部表情肌萎缩的定量超声图像与临床表现的相关性研究,为针灸临床及科学研究提供客观指标。方法:随机选取临床已出现面肌萎缩症状的患者30例为观察组,临床未出现面肌萎缩症状的患者30例为对照组,采用高频超声检测患者双侧面部表情肌厚度、平均回声强度及肌纤维改变并分析,为诊断面肌萎缩提供客观影像学依据。 结果:观察组健-患侧面部表情肌厚度对比有统计学意义(P<0.01);表情肌厚度改变、平均回声信号改变与面肌萎缩具有明显相关性,肌纤维改变与面肌萎缩治疗及预后相关。对照组健-患侧面部表情肌厚度对比无统计学意义(P>0.05),平均回声信号较健侧无明显改变,肌纤维改变与治疗及预后相关。结论:面肌萎缩患者表情肌超声表现明显异常,肌肉厚度改变、平均回声强度改变及肌纤维改变是评价面肌萎缩及判断预后的可靠观察指标,超声定量评估面肌萎缩可为临床治疗及科研工作提供客观依据,值得临床推广应用。
英文摘要:
      Objective: This study conducted an objective indicator for the quantitative ultrasound image and clinical manifestation of facial expression muscle atrophy, which provides objective indicators for acupuncture clinical and scientific research. Methods: 30 patients with clinical atrophy symptoms have been selected for the observation group, 30 patients with clinical noisy atrophy symptoms, using high-frequency ultrasonic detection patients, bilateral facial expression muscle thickness, mean echo strength And the mild fiber changes and analyzed, providing objective imaging based on diagnosis of surface muscle atrophy. Results: Observation Group Jun - The thickness of the side facial expression muscle has statistically significant (P <0.01); expression muscle thickness change, the average echo signal change and the atrophy of myopathy have significant correlation, muscle fiber changes and myocardial atrophy treatment and prognosis Related. The control group health-affected side facial expression muscle thickness contrast was not statistically significant (P> 0.05), and the average echo signal had no significant changes in the aerial side, and the muscle fiber change and the treatment and prognosis. Conclusion: Ultrasound in the expression muscle ultrasound in patients with myocardia, the muscle thickness change, the average echo intensity change and myocardial change are the reliable observation indicators of evaluation of muscle atrophy and judgment prognosis, and ultrasonic quantitative assessment of myocardial atrophy can be clinical treatment and research work. Provide objective basis for clinical promotion applications. Key words: surrounding facial paralysis; laminate; facial ultrasound; thickness comparison; clinical relevance.